PPA1500 – Academics, Development and Test

High Performance Compact Power Analyzer

The PPA1500 Power Analyzer offers higher performance than its sibling – the  PPA500 unit, the PPA1500 series ensures that N4L power analyzers provide the optimum solution in almost any power measurement application and budget. The main differences between the PPA500 and PPA1500 Power Analyzers are that the PPA1500 features a 1Mhz Bandwidth and full graphical display, this includes harmonic bar graphs and graphical data logging. The PPA1500 Power Analyzers now features sophisticated parallel digital filtering algorithms enabling the PPA1500 to be used in various Pulse Width Modulated applications. While being only half rack width and 2U high, the PPA1500 is available in 1, 2 or 3 phase configurations and offers a level of performance normally found only in larger and more costly instruments. With modes such as “Inrush Current and “Standby Power”, the PPA1500 provides fast, accurate and easy measurements in challenging environments.

The PPA1500 series analyzers now have a 6 Phase 2U Rack option in which two PPA1530 units are installed on the same rack side by side, see our accessories page for more details. For a practical insight into the versatility and speed of the PPA1500, please take a look at our Power Analyzer Tutorials.

All PPA1500 units are supplied with UKAS ISO17025 certification as standard, this is performed at N4L in the UK in our accredited ISO17025 Laboratory.

Product Images

ISO17025 Calibration and Verification

Every PPA1500 Power Analyzer supplied by N4L is provided with both a UKAS Accredited calibration certificate up to 850Hz, as well as a UKAS Traceable calibration certificate up to 1MHz. N4L have developed a number of bespoke power calibrators in order to verify the accuracy of every power analyzer supplied over its entire frequency range, this is surprisingly uncommon within the instrumentation industry. Furthermore, development of an ISO17025 (UKAS) accredited Closed Loop Calorimeter in partnership with Oxford University (UK) has verified the performance of the N4L custom designed power calibration rigs with a very low uncertainty level, providing absolute confidence that the wide band performance of all N4L power analyzers is market leading.

Calibration Options

1. Standard Recalibration – Included with new instruments – Included with RMA Calibration
Wideband calibration (DC-2MHz) with optimisation of measurements on all ranges over the complete instrument bandwidth. Traceable to UKAS but not ‘accredited’.
4. UKAS IEC61000 H+F Calibration – Optional with new instruments or RMA calibration
UKAS accredited calibration of PPA55x1 series units that includes all prevailing type test protocols for fully compliant Harmonic and Flicker testing.
This option can only be specified in addition to option 1 and option 2 calibration.
2. UKAS (ISO17025) Calibration – Included with new instruments – Optional with RMA Calibration
UKAS Accredited calibration of Voltage, Current, Phase (PF) and Power on all ranges from 55-850Hz.
In addition to the calibration certificates, the PPA will be fitted with a UKAS calibration label. This option can only be specified in addition to option 1.


5. PPA55xx-TE Calibration – Included with PPA-TE order – Optional with RMA Calibration
UKAS calibration that includes a series of low power factor tests down to 0.01 PF over the frequency range of 16-450Hz.
This option can only be specified in addition to option 1 and option 2 calibration

3. System Calibration – Optional with new instruments or RMA calibration
UKAS accredited calibration of a PPA together with an external sensor.
This option is separate to option 1 & 2 which must both be specified in addition when system calibration is required.
Note: This is end-to-end calibration of the of the PPA+sensor ‘system’ at nine N4L defined test points. (3 current levels @ 3 different frequencies)
6. UKAS calorimeter power calibration – Optional with new instruments or RMA calibration
UKAS accredited power calibration via calorimetry. Available at customer requested frequency(s) and with sinusoidal or harmonically distorted wave shapes within a frequency range of 45Hz to 2MHz.
This option can only be specified in addition to option 1 and option 2 calibration

Features & Benefits

0.05% Basic accuracy Frequency range DC and 10mHz to 1MHz
High precision internal shunts – Superior accuracy to any external shunt 10 millidegree phase accuracy – Necessary for low power factor applications
20 Arms (300 Apk) & 1000 Vrms (2500 Vpk) direct input Unique x10 gain mode for Standby Power measurement
1MS/s High speed sampling on all channels True real time analysis with no measurement gap
1, 2 or 3 phase versions High contrast full colour graphic display
Simple BNC connection of N4L shunts for high current applications RS232, USB, LAN, Extension and Auxiliary ports

Brochure Documentation
PPA5_1500 Datasheet PDF, 1Mb PPA5xx_15xx User Manual v4.0PDF, 661kb
PPA1530-Dimensions PDF, 76kb PPA5xx_15xx Comms Manual v4.0 PDF, 861kb
PPA5xx PPA15xx Rack Dimensions PDF,65kb PPA5xx_15xx-Start-up-guide-v4.00.pdf PDF, 3.1Mb
PPA Datalogger User Manual PDF, 3.31Mb Power_Analyzer_Product_Selector PDF, 236kb
PPA Datalogger Brochure PDF, 2Mb PPA Series Calibration Guide
Precision Power Analyzer design Philosophies PDF, 3.1Mb  

PPA1500

PPA1500 Options, Software and Accessories

COMMS_ICON Communications Interfaces:
  • Standard: LAN, USB and RS232 Communication Ports
  • Optional: GPIB Communication Port
PROBE_ICON Probes and Probe Accessory Options:
  • ULCP Ultra Low Capacitance Probes (Active, For use with DUT’s susceptible to capacitive loading) – 1.5pF, 1000Vrms, dc to 2MHz, 1000:1
  • TT-HV 250 High Voltage Probe (Passive) – 2.5kVpk, 100:1
  • TT-HVP 15HF High Voltage Probe – 15kVpk, 1000:1
  • ATT10 – 10:1 Attenuator (For use when voltage probe output does not meet PPA ext. input 3Vpk max rating) – For connection to PPA ext input and external attenuating probes.
  • ATT20 – 20:1 Attenuator (For use when voltage probe output does not meet PPA ext. input 3Vpk max rating) – For connection to PPA ext input and external attenuating probes.
EXTENSION_ICON Extension Port and Accessory Options:
  • PCIS – Phase controlled inrush for (Use when control of DUT source with respect to phase angle is required)
CONNECTOR_ICON Leads, Connection and Interface Options:
  • 36A Connection lead set for one phase (supplied as standard) – 36A rated, 1.5m long + Alligator Clips
  • Voltage Breakout Lead set – 3 x 2m BNC to BNC with 4mm Banana Voltage break out leads + 2 x voltage low shorting leads (For use when distance between analyser and DUT is large and HF series external shunt is being used, facilitates short voltage connections.
  • Universal Breakout Box – Single Phase 10Arms Universal Breakout box
  • RS232 Cable (Supplied as Standard) – 9 Pin null modem cable
  • USB Cable (Supplied as standard) – 2m long A Male to B Male USB Cable
CASES_ICON Carry Cases:
  • PPA5/15xx Soft Carry Case – Black Nylon Padded Case with accessory space, handle and strap
  • PPA5/15xx Hard Carry Case – PPA5/15xx Hard Aluminium Flight Case with accessory space, handle and lock (Ideal for Aircraft Hold)
RACK_ICON Rack Mounting Kit Options:
CALIBRATION_ICON Calibration and Documentation (Unit supplied with UKAS ISO17025 certificate as standard when new):
CLAMP_ICON Current Measurement Options:
PC_ICON PC Software (Free of charge):

Application Notes Related Articles

Video Tutorials

Tutorial 1 : Power Analyzer Turn on and External Shunt Configuration

Tutorial 2 : PWM Motor Drive Efficiency Measurements

Tutorial 2a : PWM Motor Driver Efficiency Measurements (Extended version)

Tutorial 3 : Standby Power Measurement of a USB Mains Adaptor

Tutorial 4 : AC/DC Converter Efficiency Measurements

Application Notes

For application notes please see the app note section of our Knowledge Database

Parameter
Frequency Range
Bandwidth DC, 10mHz ~ 1MHz

x10 DC, 10mHz ~ 100kHz

Voltage Input
Internal Ranges Normal : 1Vpk ~ 2500Vpk (8 ranges = 1V, 3V, 10V, 30V, 100V, 300V, 1KV, 3KV)

x10 100mVpk ~ 300Vpk (8 ranges = 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 300V)

Internal Accuracy Normal : 0.05% Rdg + 0.1% Rng + (0.005%xkHz) + 5mV

x10 : 0.05% Rdg + 0.1% Rng + (0.01%xkHz) + 1mV

External Voltage BNC Input Ranges 1mVpk ~ 3Vpk [BNC Connector 3Vpk Max Input] 8 Ranges = 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V
External Voltage Input Accuracy 0.05% Rdg + 0.1% Rng + (0.005%xkHz) + 5uV
Current Input
PPA1500 20Arms Shunt, 4mm Safety Connectors Normal : 100mApk ~ 300Apk (20Arms) (8 ranges = 100mA, 300mA, 1A, 3A, 10A, 30A, 100A, 300A)

x10 : 10mApk ~ 300Apk (8 ranges = 10mA, 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A)

PPA1500-HC 30Arms Shunt, 4mm Safety Connectors Normal : 300mApk ~ 1000Apk (30Arms) (8 ranges = 300mA, 1A, 3A, 10A, 30A, 100A, 300A, 1KA)

x10 : 30mApk ~ 100Apk (8 ranges = 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A, 100A)

Internal Shunt Accuracy 20Arms Normal : 0.05% Rdg + 0.1% Rng + 0.005%xkHz) + 500uA

x10 : 0.05% Rdg + 0.1% Rng + 0.01%xkHz) + 100uA

Internal Shunt Accuracy HC 30Arms Normal : 0.05% Rdg + 0.1% Rng + 0.005%xkHz) + 1mA

x10 : 0.05% Rdg + 0.1% Rng + 0.01%xkHz) + 300uA

External Current BNC Input Ranges 1mVpk ~ 3Vpk 8 Ranges = 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V
External Current Input Accuracy 0.05% Rdg + 0.1% Rng + (0.005%/kHz) + 5uV
Phase Accuracy
Normal 0.01deg + (0.01deg/kHz)
x10 0.01deg + (0.02deg/kHz)
Power Accuracy
Normal [0.1% + 0.1%/pf + (0.01%/kHz)/pf] Rdg + 0.1% VA Rng
x10 [0.1% + 0.1%/pf + (0.02%/kHz)/pf] Rdg + 0.1% VA Rng
40Hz ~ 850Hz As above with range error reduced from +0.1% V,A,VA Rng to +0.05% V,A, VA Rng
General
Crest Factor 20 (Voltage and Current)
Sample Rate 1Ms/s on all channels, real time No-Gap
IEC Compliant Modes IEC62301/EN50564 Standby Power Mode
Application Modes Ballast, Inrush, Standby Power
CMRR – Common Mode Rejection Ratio 250V @ 50Hz – ≥ 1mA (150dB) 100V @ 100kHz – ≥ 3mA (130dB)
Measurement Parameters W, VA, Var, pf, V & A – rms, rectified mean, AC, DC, peak, surge, crest factor, form factor, star to delta conversion, delta to star conversion
Frequency (Hz), Phase (deg), Fundamentals, Impedance
Harmonics, THD, TIF, THF, TRD, TDD
Integrated Values, Datalog, Sum and Neutral Values
Datalog (Up to 4 user selectable measurement functions (60 with PC software)
Datalog window No-Gap analysis, Minimum Window 10ms
Memory RAM up to 16,000 records
Communication Ports RS232, LAN, (Option L), USB, Extension (Aux)
Standard Accessories
Leads Power, RS232, USB
Connection Cables 20A (Std Version) or 30A (HC version) 1.5m long 4mm stackable terminals. 1x red, 1x yellow, 2x black per phase
Connection Clips 4mm terminated alligator clips – 1x red, 1x yellow and 2x black per phase
Instruction manual User manual, Communications manual
Other documents Calibration certificate, Quick start guide
Mechanical and Environmental
Display 480×272 dot full colour TFT, White LED backlit
Dimensions 92H x 215W x 312D mm excluding feet
Weight 3.3kg (1 Phase), 4kg (3 Phase)
Safety Isolation 1000Vrms or DC (CATII), 600Vrms or DC (CATIII)
Power Supply 90 ~ 265Vrms, 50 ~ 60Hz, 40VA Max
Operating Conditions 5 deg to 40 deg ambient temperature (or air intake temperature when rack mounted), 20-90% Non-condensing relative humidity.