IEC61000 EMC Test Systems – ISO17025 Accredited

Fully Compliant IEC61000 EMC Test Systems (IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12, IEC61000-4-11, IEC61000-4-13, IEC61000-4-17, IEC61000-4-29)

N4L’s range of IEC61000 EMC test systems offer a complete turn key solution for EMC immunity testing. The combination of the N4A AC+DC Power Source, PPA55x1 and Impedance Networks, as well as intuitive EMC test software (IECSoft) result in a simple, convenient, compliant test package.

N4L are the only IEC61000 EMC test system manufacturer in the world* with an on site UKAS ISO17025 calibration laboratory offering accreditation to IEC61000-3-2, IEC61000-3-3, IEC61000-4-7 and IEC61000-4-15. Calibration and trace-ability are a vital aspect of any EMC test solution and the coverage provided through N4L’s UKAS Laboratory is comprehensive. N4L’s IEC61000-4-15 calibration procedure is particularly noteworthy as it covers the entire test protocol detailed in Annex C of IEC61000-4-15. It is commonplace for specific parameters within IEC61000-4-15 (d parameters are frequently omitted from calibration procedures) to remain untested during typical flicker calibration due to the difficulty in providing trace-ability for such measurements. All tests within the test protocol of Annex C are included within the scope of accreditation and calibration procedures at N4L.

IECSoft is an integral component of the EMC test package, integrating the various hardware components and displaying the data in a clear manner. As an example of IECSoft’s flexibility, the user is able to send comprehensive test data to external customers or colleagues within the design department. This is useful as design engineers are able to replay Harmonics and Flicker tests in real time, allowing visualization of not only the results of the tests (in report form), but also determination of the devices performance throughout the test. An example of this may be that the final report of an IEC61000-3-2 test results in the EUT(Equipment under test) failing on Harmonic 5, IECSoft can replay the behavior of harmonic 5 throughout the test which can significantly reduce debugging time for the design engineer in the event of such a failed compliance test. In the past EMC test systems would only offer details of the harmonic failure levels in summary form, with an N4L EMC test system no such restrictions apply.

Product Images

Example Test System Configurations

Below are example test system configurations which provide compliant Harmonics and Flicker test solutions to the latest IEC/EN standards listed in the table at the top of this page. The PPA55x1 is fully compliant IEC 61000-4-7: 2002+A1:2008 and IEC 61000-4-15: 2010 (Ed.2).

3kVA (10Arms max) Single Phase IEC61000 EMC Test system

Measurement Requirement
Compliance
Analyzer
Impedance Network
Calibration (optional)
AC Source
IEC61000 EMC Testing

10Arms Single Phase
IEC61000-3-2
IEC61000-3-3
IEC61000-4-11*
IEC61000-4-13
IEC61000-4-14
IEC61000-4-17
IEC61000-4-28
IEC61000-4-29*
PPA5500 Power Analyzer Front View no bg chopped 200px

PPA5511 Harmonics and Flicker Analyzer

+
IMP161 Front Panel 200px

IMP161 Impedance Network

+
UKAS_Logo
+

n4a06_small
N4A03 Programmable Power Source

6kVA (20Arms max) Single Phase IEC61000 EMC Test system

Measurement Requirement
Compliance
Analyzer
Impedance Network
Calibration (optional)
AC Source
IEC61000 EMC Testing

16Arms Single Phase
IEC61000-3-2
IEC61000-3-3
IEC61000-4-11*
IEC61000-4-13
IEC61000-4-14
IEC61000-4-17
IEC61000-4-28
IEC61000-4-29*
PPA5500 Power Analyzer Front View no bg chopped 200px

PPA5511 Harmonics and Flicker Analyzer

+
IMP161 Front Panel 200px

IMP161 Impedance Network

+
UKAS_Logo
+

n4a06_small
N4A06 Programmable Power Source

18kVA (20Arms max/phase) Three Phase IEC61000 EMC Test system

Measurement Requirement
Compliance
Analyzer
Impedance Network
Calibration (optional)
AC Source
IEC61000 EMC Testing

20Arms/phase Three Phase
IEC61000-3-2
IEC61000-3-3
IEC61000-3-11
IEC61000-3-12
IEC61000-4-11*
IEC61000-4-13
IEC61000-4-14
IEC61000-4-17
IEC61000-4-28
IEC61000-4-29*
IEC61000-4-34*
PPA5500 Power Analyzer Front View no bg chopped 200px

PPA5531 Harmonics and Flicker Analyzer

+
IMP161 Front Panel 200px

IMP163 Impedance Network (IMP161 pictured)

+
UKAS_Logo
+

n4a06_small
N4A18 Programmable Power Source (N4A03 Pictured)

30kVA (32Arms max/phase) Three Phase IEC61000 EMC Test System

Measurement Requirement
Compliance
Analyzer
Impedance Network
Calibration (optional)
AC Source
IEC61000 EMC Testing

32Arms/phase Three Phase
IEC61000-3-2
IEC61000-3-3
IEC61000-3-11
IEC61000-3-12
IEC61000-4-11*
IEC61000-4-13
IEC61000-4-14
IEC61000-4-17
IEC61000-4-28
IEC61000-4-29*
IEC61000-4-34*
PPA5500 Power Analyzer Front View no bg chopped 200px

PPA5531 Harmonics and Flicker Analyzer

+
IMP161 Front Panel 200px

IMP323 Impedance Network (IMP161 pictured)

+
UKAS_Logo
+

n4a06_small
N4A30 Programmable Power Source (N4A03 Pictured)

67kVA (75Arms max/phase) Three Phase IEC61000 EMC Test System

Measurement Requirement
Compliance
Analyzer
Impedance Network
LEM IT200-S CTs & LEM-1 Interface
System Calibration
AC Source
IEC61000 EMC Testing

75Arms/phase Three Phase
IEC61000-3-2
IEC61000-3-3
IEC61000-3-11
IEC61000-3-12
IEC61000-4-11*
IEC61000-4-13
IEC61000-4-14
IEC61000-4-17
IEC61000-4-28
IEC61000-4-29*
IEC61000-4-34*

ppa55x1 flickermeter
PPA5531 Harmonics and Flicker Analyzer

+
IMP161 Front Panel 200px

IMP753 Impedance Network (IMP161 pictured)

+

LEM-1 Interface
3x LEM-1 Interface + PSU + 3x IT200-S

+
UKAS_Logo
+
N4A67 Programmable Power Source

N4A67 Programmable Power Source (N4A06 pictured)

*Full compliance requires external switching, please contact us for more information

Features & Benefits

0.01% Basic accuracy Frequency range DC and 10mHz to 1MHz
Fully compliant IEC61000-3-2 including  IEC61000-3-2:2018+A1:2020(Ed5.1 2020-07) Fully compliant IEC61000-3-3 including IEC61000-3-3:2013+A1:2017 2017+A2:2022 COR1:2022
Fully compliant IEC61000-3-11 Fully compliant IEC61000-3-12
Part compliant IEC61000-4-11 Fully compliant IEC61000-4-13
Fully compliant IEC61000-4-14 Fully compliant IEC61000-4-28
Pre compliant IEC61000-4-29 Fully compliant IEC61000-4-34
High precision internal shunts Superior accuracy to any external shunt 5 millidegree phase accuracy Necessary for low power factor applications
50 Arms (1000 Apk) & 1000 Vrms (3000 Vpk) direct input Standard current (50Arms) options
High speed sampling on all channels True real time analysis with no measurement gap
1, 2 or 3 phase versions
master – slave mode for 4, 5 or 6 phase
Real time Digital, Tabular, Graphic and Oscilloscope displays
Simple BNC connection of N4L shunts for high current applications RS232, IEEE 488, USB, LAN, Torque, Speed and Extension ports